Case Analysis of Glass Curtain Wall Project Outside a Building
American Journal of Civil Engineering
Volume 4, Issue 6, November 2016, Pages: 360-366
Received: Dec. 6, 2016; Published: Dec. 9, 2016
Views 3086      Downloads 79
Authors
Yongqu Gong, College of Civil Engineering, Tongji University, Shanghai, China; Shanghai Zhongjian Eighth Engineering Diversion Decoration CORP. LTD, Shanghai, China
Qiang Xu, College of Civil Engineering, Tongji University, Shanghai, China
Article Tools
Follow on us
Abstract
Taking Nanjing Zhongjian Mansion as an example, the choice of curtain wall type is analyzed and the organization of the construction of the project is analyzed in details. The key measures of the quality assurance of glass curtain wall are discussed from the angle of construction. In this case analysis, the glass curtain wall engineering quality control of specific and curtain wall engineering quality control features have been study.
Keywords
Curtain Wall, Glass Curtain, Glass Canopy
To cite this article
Yongqu Gong, Qiang Xu, Case Analysis of Glass Curtain Wall Project Outside a Building, American Journal of Civil Engineering. Vol. 4, No. 6, 2016, pp. 360-366. doi: 10.11648/j.ajce.20160406.23
References
[1]
Construction Technology and Application of Curtain Wall [J]. Shanxi Architecture, 2011, 09: 107-108.
[2]
LIU Hai-Liang. Discussion on Curtain Wall Project Management from the Problems Existing in a Project Management [J]. Construction Technology, 2008, 02: 12-14.
[3]
Technical Code for Glass Curtain Wall Engineering JBJ102-2013.
[4]
China Standard Publishing House second editing room. Building curtain wall standard compilation [M]. Beijing: China Standard Press, 2004. 3.
[5]
Qiu Jianhui, Huang Bai. Building curtain wall industry technical standards specification compilation [M]. Beijing: China Building Industry Press, 2004.3. https://www.glassonweb.com/news/gpad-2017-glass-processing-automation-days.
[6]
Ai Hongyuan, Zhou Xiangguang, Dai Jinggan. Modern architectural curtain wall design Record [M]. Nanjing: Southeast University Press, 2003. 3.
[7]
Mu Xiaoqiang. On the curtain wall anti-leakage and control measures to explore, building materials, decoration, in November 2014.
[8]
Baniotopoulos, C. C.. Optimal structural design of glass curtain-wall systems [J]. Proceedings of the Institution of Civil Engineers-Structures and Buildings, 2016, 01: 450-457.
[9]
Wang, Y. W. A Practical Tool Used to Compute Thermal Performance of Glass Curtain Walls [J]. Structural Engineering International, 2016, 05: 114-120.
[10]
Lu, Wensheng, Experimental evaluation of a glass curtain wall of a tall building [J]. Earthquake Engineering & Structural Dynamic, 2016, 01: 1185-1205.
[11]
Kong, Xiangfei, An experimental study of all-season operation strategy for a respiration-type double-layer glass curtain wall system in cold zone of China [J]. Building and Environment, 2016, 02: 166-176.