| Peer-Reviewed

A Fuzzy Logic Distance Relay

Received: 10 October 2014    Accepted: 29 October 2014    Published: 30 October 2014
Views:       Downloads:
Abstract

This paper presents a new approach to protect the transmission line by a design and implementation of distance relay using Fuzzy logic module. The proposed module uses sample of voltage and current signals to calculate line impedance (ZL). Simulation studies are performed and influence of changing system parameters such as type of faults like single line to ground fault, three phase to ground fault and double line to ground fault, also fault resistance and fault location; were taken the results show that the module respond in a very high speed relay, the performance of this distance relay is fast and accurate as compared with other relays the detection is with in less than 1⁄8 of the period.

Published in American Journal of Electrical Power and Energy Systems (Volume 3, Issue 5)
DOI 10.11648/j.epes.20140305.12
Page(s) 95-100
Creative Commons

This is an Open Access article, distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution and reproduction in any medium or format, provided the original work is properly cited.

Copyright

Copyright © The Author(s), 2024. Published by Science Publishing Group

Keywords

Transmission Line, Distance Relay, Fuzzy Logic, Matlab-Simulink

References
[1] M. Sanaye-Pasand , and H . Khorashadi-Zadeh , An Extended ANN-Based High Speed Accurate Distance Protection Algorithm , Electrical Power and Energy Systems 25, January, 2006.
[2] M. F. Al-Kababji, Real Time Based Fuzzy Logic Distance Protection, Al-Rafidain engineering, Vol.20, No. 3, June, 2012.
[3] Network Protection and Automation Guide, Alstom grid, May, 2011.
[4] W. W. L. Keerthipala , Huisheng Wang , Chan Tat Wai, On-Line Testing of a Fuzzy-Nleuro based Protective Relay using a Real-Time Digital Simulator, IEEE, Journal: Power Engineering Society Winter Meeting ,vol .3,2000.
[5] K. Erenturk , A New Digital Protective Relay Based on Fuzzy Logic and Value Estimation , Iranian Journal of Science and Technology, transaction A, Vol.29, No.A2, 2005 .
Cite This Article
  • APA Style

    Maamoon Fadhel Al-Kababjie, Muhamed Nashwan Al-Kaleajie. (2014). A Fuzzy Logic Distance Relay. American Journal of Electrical Power and Energy Systems, 3(5), 95-100. https://doi.org/10.11648/j.epes.20140305.12

    Copy | Download

    ACS Style

    Maamoon Fadhel Al-Kababjie; Muhamed Nashwan Al-Kaleajie. A Fuzzy Logic Distance Relay. Am. J. Electr. Power Energy Syst. 2014, 3(5), 95-100. doi: 10.11648/j.epes.20140305.12

    Copy | Download

    AMA Style

    Maamoon Fadhel Al-Kababjie, Muhamed Nashwan Al-Kaleajie. A Fuzzy Logic Distance Relay. Am J Electr Power Energy Syst. 2014;3(5):95-100. doi: 10.11648/j.epes.20140305.12

    Copy | Download

  • @article{10.11648/j.epes.20140305.12,
      author = {Maamoon Fadhel Al-Kababjie and Muhamed Nashwan Al-Kaleajie},
      title = {A Fuzzy Logic Distance Relay},
      journal = {American Journal of Electrical Power and Energy Systems},
      volume = {3},
      number = {5},
      pages = {95-100},
      doi = {10.11648/j.epes.20140305.12},
      url = {https://doi.org/10.11648/j.epes.20140305.12},
      eprint = {https://article.sciencepublishinggroup.com/pdf/10.11648.j.epes.20140305.12},
      abstract = {This paper presents a new approach to protect the transmission line by a design and implementation of distance relay using Fuzzy logic module. The proposed module uses sample of voltage and current signals to calculate line impedance (ZL). Simulation studies are performed and influence of changing system parameters such as type of faults like single line to ground fault, three phase to ground fault and double line to ground fault, also fault resistance and fault location; were taken the results show that the module respond in a very high speed relay, the performance of this distance relay is fast and accurate as compared with other relays the detection is with in less than 1⁄8  of the period.},
     year = {2014}
    }
    

    Copy | Download

  • TY  - JOUR
    T1  - A Fuzzy Logic Distance Relay
    AU  - Maamoon Fadhel Al-Kababjie
    AU  - Muhamed Nashwan Al-Kaleajie
    Y1  - 2014/10/30
    PY  - 2014
    N1  - https://doi.org/10.11648/j.epes.20140305.12
    DO  - 10.11648/j.epes.20140305.12
    T2  - American Journal of Electrical Power and Energy Systems
    JF  - American Journal of Electrical Power and Energy Systems
    JO  - American Journal of Electrical Power and Energy Systems
    SP  - 95
    EP  - 100
    PB  - Science Publishing Group
    SN  - 2326-9200
    UR  - https://doi.org/10.11648/j.epes.20140305.12
    AB  - This paper presents a new approach to protect the transmission line by a design and implementation of distance relay using Fuzzy logic module. The proposed module uses sample of voltage and current signals to calculate line impedance (ZL). Simulation studies are performed and influence of changing system parameters such as type of faults like single line to ground fault, three phase to ground fault and double line to ground fault, also fault resistance and fault location; were taken the results show that the module respond in a very high speed relay, the performance of this distance relay is fast and accurate as compared with other relays the detection is with in less than 1⁄8  of the period.
    VL  - 3
    IS  - 5
    ER  - 

    Copy | Download

Author Information
  • Electrical Engineering Department, University of Mosul, Mosul, Iraq

  • Electrical Engineering Department, University of Mosul, Mosul, Iraq

  • Sections