Dynamic Response Analysis of Simply Supported Steel Beam Under Natural Fire Field Load
Science Discovery
Volume 5, Issue 7, December 2017, Pages: 603-608
Received: Dec. 28, 2017; Published: Jan. 7, 2018
Views 51      Downloads 7
Authors
Tang Feng, College of Engineering, Hunan Agricultural University, Changsha, China
Yang Jinglin, College of Engineering, Hunan Agricultural University, Changsha, China
Wan Linhui, College of Engineering, Hunan Agricultural University, Changsha, China
Ou Yangguoyuan, College of Engineering, Hunan Agricultural University, Changsha, China
Article Tools
Follow on us
Abstract
The outbreak of fire has a great influence on. the carrying capacity of structure. the elastic modulus, flexural rigidity, yield strength and natural frequency of structural steel are discussed on the effects of fire temperature in this paper. The simply supported steel beam to form a plastic hinge when the ultimate moment changes in the first phase of the beam movement and the dynamic responses of simply supported steel beams under different loads were analyzed. Specific to the Q235 H-shaped steel case of H-shaped steel was calculated in high temperature structural steel bending stiffness, yield strength and natural frequency of simply supported steel beam in the two stages of movement of the dynamic response is analyzed. The analysis showed that the fire duration was 2.5h, the yield strength of steel is only 85.63N/mm2, a drop of 63.56%, while the component in the fire field in two phases dynamic deflection is also rapid growth, an increase of over 50%, almost lost capacity, in addition to members of this excessive plastic deformation is a serious cause of the damaged component. Dangerous. Therefore, in order to ensure the safety of steel structure design, the adverse effects should be taken into full consideration in the design of simply supported steel beams.
Keywords
Fire Field, Simply Supported Steel Beam, Bearing Capacity, Ultimate Bending Moment, Dynamic Response
To cite this article
Tang Feng, Yang Jinglin, Wan Linhui, Ou Yangguoyuan, Dynamic Response Analysis of Simply Supported Steel Beam Under Natural Fire Field Load, Science Discovery. Vol. 5, No. 7, 2017, pp. 603-608. doi: 10.11648/j.sd.20170507.32
References
[1]
李国强,蒋首超,林桂祥.钢结构抗火计算与设计[M].北京:中国建筑工业出版社,1999.6:75-102。
[2]
余同希.冲击荷载作用下材料和结构的响应[J].力学进展,1997.27(2):276-280。
[3]
杨桂通.塑性动力学[M].北京:高等教育出版社,2000:93-102。
[4]
杨桂通.结构在冲击荷载作用下的实验研究[J].力学学报,1990.22(3):374-379。
[5]
Yu T X, Yang J L Reid S R. Dynamic behavior of elastic-plastic free-free beams subjected to impulsive loading Int J Solids Structures [J]. 1996, 33:2659-2680.
[6]
王振清,韩玉来,王永军,苏娟.火灾场冲击波荷载作用下简支钢梁动力响应[J].振动与冲击,2007.26(4):69-72,170。
[7]
赵启超,孙胜.火灾场冲击波荷载作用下刚塑性简支钢梁的残余变形[J].黑龙江科技信息,2011,7(7):314。
[8]
王振清,韩玉来,苏娟,乔牧.钢筋混凝土梁火灾承载力及等效楼面荷载分析[J].武汉理工大学学报,2007.29(6):65-68。
[9]
GB50017-2003钢结构设计规范[S].北京:中国计划出版社,2003。
[10]
朱婉婉.通风系数对钢构件的耐火性能影响研究[J].武警学院学报,2016,32(8):9-12。
[11]
张之峰,石国峰.受火钢结构温度-结构耦合场分析[J].电脑知识与技术,2015,11(2):260-262。
ADDRESS
Science Publishing Group
548 FASHION AVENUE
NEW YORK, NY 10018
U.S.A.
Tel: (001)347-688-8931