| Peer-Reviewed

Analysis and Evaluation of Structural Safety Inspection of a Railway Station

Received: 31 August 2020    Accepted:     Published: 17 October 2020
Views:       Downloads:
Abstract

Based on the structural safety inspection of a railway station, first the current status and damage of the housing structure are introduced. It is analysed in this paper the safe capability of the railway station via precise on-site testing work. It is further discussed the influence of different modeling methods on the calculative results of the compressive bearing capacity of buttress column used in this masory structure. There is no software could accurately simulate the compressive bearing capacity of buttress column, for it is difficult to meet the actual needs of the project. This paper could be valuable future reference for the safety inspection and strengthening scheme of similar projects.

Published in Science Discovery (Volume 8, Issue 5)
DOI 10.11648/j.sd.20200805.14
Page(s) 97-100
Creative Commons

This is an Open Access article, distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution and reproduction in any medium or format, provided the original work is properly cited.

Copyright

Copyright © The Author(s), 2024. Published by Science Publishing Group

Keywords

Masory Structure, Structural Safty, Buttress Column

References
[1] 砌体工程现场检测技术标准:GB/T50315-2011[S].北京:中国建筑工业出版社,2011.
[2] 建筑结构检测技术标准:GB/T 50344-2019[S].北京: 中国建筑工业出版社,2019.
[3] 砌体结构设计规范:GB50003-2012[S].北京:中国建筑工业出版社,2011.
[4] 郭行方.既有砌体砖墙检测鉴定方法及加固对比分析[J].福建建设科技,2020,2:5-7.
[5] 陈瑜,陆伟东,杨放.南京民国建筑的结构安全特点及抗震鉴定研究[J]. 建筑技术,2013,44(2):157-160.
[6] 危险房屋鉴定标准:JGJ125-2016[S].北京:中国建筑工业出版社,2016.
[7] 李满枝,张小琼.上海某砌体结构厂房检测与加层加固设计[C]. 2020年工业建筑学术交流会论文集(上册).
[8] 马东亚,金刚.某砌体砌体结构加固设计[J].建筑结构,2019,49(增刊):711-715.
[9] 房屋质量检测规程:DG/TJ 08-79-2008[S].北京:中国建筑工业出版社,2011.
[10] 喻云龙,李世宏等.既有老旧房屋砂浆及砌体强度现场试验研究[J].建筑结构,2019,49(5):23-26.
Cite This Article
  • APA Style

    Guo Xiaoyan, Fang Lin, Ma Zefeng. (2020). Analysis and Evaluation of Structural Safety Inspection of a Railway Station. Science Discovery, 8(5), 97-100. https://doi.org/10.11648/j.sd.20200805.14

    Copy | Download

    ACS Style

    Guo Xiaoyan; Fang Lin; Ma Zefeng. Analysis and Evaluation of Structural Safety Inspection of a Railway Station. Sci. Discov. 2020, 8(5), 97-100. doi: 10.11648/j.sd.20200805.14

    Copy | Download

    AMA Style

    Guo Xiaoyan, Fang Lin, Ma Zefeng. Analysis and Evaluation of Structural Safety Inspection of a Railway Station. Sci Discov. 2020;8(5):97-100. doi: 10.11648/j.sd.20200805.14

    Copy | Download

  • @article{10.11648/j.sd.20200805.14,
      author = {Guo Xiaoyan and Fang Lin and Ma Zefeng},
      title = {Analysis and Evaluation of Structural Safety Inspection of a Railway Station},
      journal = {Science Discovery},
      volume = {8},
      number = {5},
      pages = {97-100},
      doi = {10.11648/j.sd.20200805.14},
      url = {https://doi.org/10.11648/j.sd.20200805.14},
      eprint = {https://article.sciencepublishinggroup.com/pdf/10.11648.j.sd.20200805.14},
      abstract = {Based on the structural safety inspection of a railway station, first the current status and damage of the housing structure are introduced. It is analysed in this paper the safe capability of the railway station via precise on-site testing work. It is further discussed the influence of different modeling methods on the calculative results of the compressive bearing capacity of buttress column used in this masory structure. There is no software could accurately simulate the compressive bearing capacity of buttress column, for it is difficult to meet the actual needs of the project. This paper could be valuable future reference for the safety inspection and strengthening scheme of similar projects.},
     year = {2020}
    }
    

    Copy | Download

  • TY  - JOUR
    T1  - Analysis and Evaluation of Structural Safety Inspection of a Railway Station
    AU  - Guo Xiaoyan
    AU  - Fang Lin
    AU  - Ma Zefeng
    Y1  - 2020/10/17
    PY  - 2020
    N1  - https://doi.org/10.11648/j.sd.20200805.14
    DO  - 10.11648/j.sd.20200805.14
    T2  - Science Discovery
    JF  - Science Discovery
    JO  - Science Discovery
    SP  - 97
    EP  - 100
    PB  - Science Publishing Group
    SN  - 2331-0650
    UR  - https://doi.org/10.11648/j.sd.20200805.14
    AB  - Based on the structural safety inspection of a railway station, first the current status and damage of the housing structure are introduced. It is analysed in this paper the safe capability of the railway station via precise on-site testing work. It is further discussed the influence of different modeling methods on the calculative results of the compressive bearing capacity of buttress column used in this masory structure. There is no software could accurately simulate the compressive bearing capacity of buttress column, for it is difficult to meet the actual needs of the project. This paper could be valuable future reference for the safety inspection and strengthening scheme of similar projects.
    VL  - 8
    IS  - 5
    ER  - 

    Copy | Download

Author Information
  • Technical Center of East China Architectural Design Institute, Shanghai, China

  • Technical Center of East China Architectural Design Institute, Shanghai, China

  • Technical Center of East China Architectural Design Institute, Shanghai, China

  • Sections