| Peer-Reviewed

Research on the Reliability Evaluation of Transmission Line on-Line Monitoring Device Based on the Comprehensive Evaluation Method

Received: 25 June 2018    Accepted:     Published: 26 June 2018
Views:       Downloads:
Abstract

In view of the reliability of the on-line monitoring device for transmission lines, this paper puts forward a comprehensive evaluation method combining the analytic hierarchy process and the fuzzy evaluation method, in order to realize the reliability evaluation of the on-line monitoring device for transmission lines. Firstly, the structure of reliability evaluation system, which is composed of environmental factors, installation factors, human factors and management level factors, is established. Then, based on the evaluation system, the reliability of the on-line monitoring device for transmission lines is evaluated by fuzzy evaluation. Finally, according to the principle of maximum membership, the reliability of an on-line monitoring device for a transmission line is judged. The results show that the comprehensive evaluation method can well reflect the reliability of the on-line monitoring device for transmission lines, and provides a theoretical and practical basis for the reliability evaluation of the on-line monitoring device for transmission lines.

Published in Science Discovery (Volume 6, Issue 3)
DOI 10.11648/j.sd.20180603.20
Page(s) 199-204
Creative Commons

This is an Open Access article, distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution and reproduction in any medium or format, provided the original work is properly cited.

Copyright

Copyright © The Author(s), 2024. Published by Science Publishing Group

Keywords

Transmission Line, AHP, Fuzzy Evaluation Method, On-Line Monitoring Device, Reliability Assessment

References
[1] 徐望圣,童干,汪旭旭,秦冰.输电线路在线监测装置设备可靠性的提升措施研究[J].电气开关,2016,54(03):19-21+26。
[2] 高晓婧.基于模糊综合评判的输电线路在线监测装置综合评估[D].华北电力大学(北京),2016。
[3] 段满银,张国华.国内外直流输电系统可靠性指标对比分析[J].电网技术,2013,09:2390-2395。
[4] 曾庆禹.特高压交直流输电系统可靠性分析[J].电网技术,2013,10:2681-2688。
[5] 马为民,杨志栋,李亚男.±800kV特高压直流输电工程共用接地极的可靠性评价[J].高电压技术,2010,02:301-305。
[6] 张禄琦,周家启,刘洋,谢开贵,刘威,金小明.高压直流输电工程可靠性指标统计分析[J].电力系统自动化,2007,19:95-99。
[7] 明娇,刘代勇.基于改进层次模糊评判的地区电网AVC系统告警信息分级模型[J].电力系统保护与控制,2011,39(2):51-54。
[8] 王钦,文福拴,刘敏,等.基于模糊集理论和层次分析法的电力市场综合评价[J]. 电力系统自动化,2009,33(7):32-37。
[9] 满若岩,付忠广.基于模糊综合评判的火电厂状态评估[J]. 中国电机工程学报,2009,29(5):5-10。
[10] 何迎春.基于故障树的架空输电线路可靠性评估方法研究[D].重庆大学,2012。
[11] 段若晨,王丰华,顾承昱,满玉岩,傅正财,刘亚东. 采用改进层次分析法综合评估500kV输电线路防雷改造效果[J].高电压技术,2014,01:131-137。
[12] 黄知超,谢霞,王斌.结合模糊综合评判与决策的电力系统状态估计[J].电力系统保护与控制,2015,43(07):65-69。
[13] 郄晓和.基于灰色模糊理论的电力工程项目风险评价研究[D].华北电力大学(北京),2011。
[14] 李淼淼.基于模糊—神经网络的电力企业核心竞争力评价研究[D].河北工程大学,2011。
[15] 湛顶,董元成.多因子分层模糊评价法在输电线路防雷改造中的研究[J].电气开关,2018,56(01):9-12+17。
[16] 张科伟,施泉生. 电力企业危机管理能力的模糊评价[J]. 华东电力,2008,08:141-143。
[17] 周二雄,李凤婷,朱贺.基于改进层次分析法(AHP)的微网-成本-效益评估[J]. 电力建设,2013,34(3):1-6。
[18] 黎祚,周步祥,李君,林楠,李阳,刘金华. 考虑权重标度法的中长期负荷预测综合模型[J]. 电力系统及其自动化学报,2013,05:96-99。
[19] 黄敬尧,杨爽,郭昊,李维维. 基于层次分析法的带电跨越方式选择[J].电力建设,2013,05:106-109。
[20] 彭汝华.基于层次分析法的电力需求侧管理研究[D].重庆大学,2008。
[21] 张晶晶,许修乐,丁明,李金忠,王健一,吴超.基于模糊层次分析法的变压器状态评估[J].电力系统保护与控制,2017,45(03):75-81。
[22] 王丽丽. 模糊数学法结合层次分析法用于清洁生产潜力评估研究[D].重庆大学,2010。
[23] 梁丁相,陈曦.基于模糊综合评判理论的电力信息系统安全风险评估模型及应用[J].电力系统保护与控制,2009,37(5):61-64。
[24] 刘瑾,冯瑛敏,章辉,冯亮,孙瑞雪,王丽珠.基于熵值分析和层次分析法的智能电网电力终端接入网综合效益评价[J].电力建设,2015,05:136-140。
[25] 石雪. 电力市场运营规则评价指标体系及综合评价方法研究[D].华北电力大学(北京),2009。
Cite This Article
  • APA Style

    He Ye, Liu Bing, Chen Chao, Zhang LiHong, Pan Bo, et al. (2018). Research on the Reliability Evaluation of Transmission Line on-Line Monitoring Device Based on the Comprehensive Evaluation Method. Science Discovery, 6(3), 199-204. https://doi.org/10.11648/j.sd.20180603.20

    Copy | Download

    ACS Style

    He Ye; Liu Bing; Chen Chao; Zhang LiHong; Pan Bo, et al. Research on the Reliability Evaluation of Transmission Line on-Line Monitoring Device Based on the Comprehensive Evaluation Method. Sci. Discov. 2018, 6(3), 199-204. doi: 10.11648/j.sd.20180603.20

    Copy | Download

    AMA Style

    He Ye, Liu Bing, Chen Chao, Zhang LiHong, Pan Bo, et al. Research on the Reliability Evaluation of Transmission Line on-Line Monitoring Device Based on the Comprehensive Evaluation Method. Sci Discov. 2018;6(3):199-204. doi: 10.11648/j.sd.20180603.20

    Copy | Download

  • @article{10.11648/j.sd.20180603.20,
      author = {He Ye and Liu Bing and Chen Chao and Zhang LiHong and Pan Bo and Xiong Wei},
      title = {Research on the Reliability Evaluation of Transmission Line on-Line Monitoring Device Based on the Comprehensive Evaluation Method},
      journal = {Science Discovery},
      volume = {6},
      number = {3},
      pages = {199-204},
      doi = {10.11648/j.sd.20180603.20},
      url = {https://doi.org/10.11648/j.sd.20180603.20},
      eprint = {https://article.sciencepublishinggroup.com/pdf/10.11648.j.sd.20180603.20},
      abstract = {In view of the reliability of the on-line monitoring device for transmission lines, this paper puts forward a comprehensive evaluation method combining the analytic hierarchy process and the fuzzy evaluation method, in order to realize the reliability evaluation of the on-line monitoring device for transmission lines. Firstly, the structure of reliability evaluation system, which is composed of environmental factors, installation factors, human factors and management level factors, is established. Then, based on the evaluation system, the reliability of the on-line monitoring device for transmission lines is evaluated by fuzzy evaluation. Finally, according to the principle of maximum membership, the reliability of an on-line monitoring device for a transmission line is judged. The results show that the comprehensive evaluation method can well reflect the reliability of the on-line monitoring device for transmission lines, and provides a theoretical and practical basis for the reliability evaluation of the on-line monitoring device for transmission lines.},
     year = {2018}
    }
    

    Copy | Download

  • TY  - JOUR
    T1  - Research on the Reliability Evaluation of Transmission Line on-Line Monitoring Device Based on the Comprehensive Evaluation Method
    AU  - He Ye
    AU  - Liu Bing
    AU  - Chen Chao
    AU  - Zhang LiHong
    AU  - Pan Bo
    AU  - Xiong Wei
    Y1  - 2018/06/26
    PY  - 2018
    N1  - https://doi.org/10.11648/j.sd.20180603.20
    DO  - 10.11648/j.sd.20180603.20
    T2  - Science Discovery
    JF  - Science Discovery
    JO  - Science Discovery
    SP  - 199
    EP  - 204
    PB  - Science Publishing Group
    SN  - 2331-0650
    UR  - https://doi.org/10.11648/j.sd.20180603.20
    AB  - In view of the reliability of the on-line monitoring device for transmission lines, this paper puts forward a comprehensive evaluation method combining the analytic hierarchy process and the fuzzy evaluation method, in order to realize the reliability evaluation of the on-line monitoring device for transmission lines. Firstly, the structure of reliability evaluation system, which is composed of environmental factors, installation factors, human factors and management level factors, is established. Then, based on the evaluation system, the reliability of the on-line monitoring device for transmission lines is evaluated by fuzzy evaluation. Finally, according to the principle of maximum membership, the reliability of an on-line monitoring device for a transmission line is judged. The results show that the comprehensive evaluation method can well reflect the reliability of the on-line monitoring device for transmission lines, and provides a theoretical and practical basis for the reliability evaluation of the on-line monitoring device for transmission lines.
    VL  - 6
    IS  - 3
    ER  - 

    Copy | Download

Author Information
  • GuiZhou Power Grid Limited Liability Company Anshun Power Supply Bureau, Anshun, China

  • GuiZhou Power Grid Limited Liability Company Anshun Power Supply Bureau, Anshun, China

  • GuiZhou Power Grid Limited Liability Company Anshun Power Supply Bureau, Anshun, China

  • College of Electrical Engineering, GuiZhou University, Guiyang, China

  • College of Electrical Engineering, GuiZhou University, Guiyang, China

  • College of Electrical Engineering, GuiZhou University, Guiyang, China

  • Sections