Abstract

Foundation is a critical element for any dam. Understanding the foundation and the required treatment is critical to developing the final dam design. However, the design of the foundation does not end with the final design drawings for the Project. During construction foundation conditions need to be evaluated as excavation and construction proceeds to determine if foundation conditions are consistent with assumptions and expectations. Adjustments to the planned excavation or to the design of the dam, including changes in the grout curtain, dam geometry, and other features are often required during construction. This paper discusses the foundation conditions encountered during construction of concrete gravity dam and the associated treatments that were required. To ensure the safety of project, foundation was treated and design adjustments were made. A 2D analysis was carried out using ABAQUS Finite Element Method (FEM) software.

DOI 10.11648/j.ajce.20170506.16
Published in American Journal of Civil Engineering (Volume 5, Issue 6, November 2017)
Page(s) 352-357
Creative Commons

This is an Open Access article, distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution and reproduction in any medium or format, provided the original work is properly cited.

Copyright

Copyright © The Author(s), 2024. Published by Science Publishing Group

Keywords

Shear Zone, Dam, Foundation Treatment, Abaqus, Geology

References
[1] Concrete Dams by Dr. H. D. Sharma, Publication No.266, CBIP.
[2] Design Manual of Concrete Gravity Dams, A Water Resources Technical Publication, USBR, Denver, Colorado 1976.
[3] IS: 6066: 1994 (Reaffirmed 2004), Pressure Grouting of Rock Foundation in River Vally Projects – Recommendations.
[4] IS: 5878 (Part VII) – 1972, Code of Practice for Constructing of Tunnels Conveying Water, Part VII Grouting.
[5] IS: 6512 (Reaffirmed 1998), Criteria for Design of Solid Gravity Dams.
Cite This Article
  • APA Style

    Ashutosh Anand, Somesh Kumar, Vivek Tripathi. (2017). Shear Zone Treatment at Dam Foundation Level. American Journal of Civil Engineering, 5(6), 352-357. https://doi.org/10.11648/j.ajce.20170506.16

    Copy | Download

    ACS Style

    Ashutosh Anand; Somesh Kumar; Vivek Tripathi. Shear Zone Treatment at Dam Foundation Level. Am. J. Civ. Eng. 2017, 5(6), 352-357. doi: 10.11648/j.ajce.20170506.16

    Copy | Download

    AMA Style

    Ashutosh Anand, Somesh Kumar, Vivek Tripathi. Shear Zone Treatment at Dam Foundation Level. Am J Civ Eng. 2017;5(6):352-357. doi: 10.11648/j.ajce.20170506.16

    Copy | Download

  • @article{10.11648/j.ajce.20170506.16,
      author = {Ashutosh Anand and Somesh Kumar and Vivek Tripathi},
      title = {Shear Zone Treatment at Dam Foundation Level},
      journal = {American Journal of Civil Engineering},
      volume = {5},
      number = {6},
      pages = {352-357},
      doi = {10.11648/j.ajce.20170506.16},
      url = {https://doi.org/10.11648/j.ajce.20170506.16},
      eprint = {https://article.sciencepublishinggroup.com/pdf/10.11648.j.ajce.20170506.16},
      abstract = {Foundation is a critical element for any dam. Understanding the foundation and the required treatment is critical to developing the final dam design. However, the design of the foundation does not end with the final design drawings for the Project. During construction foundation conditions need to be evaluated as excavation and construction proceeds to determine if foundation conditions are consistent with assumptions and expectations. Adjustments to the planned excavation or to the design of the dam, including changes in the grout curtain, dam geometry, and other features are often required during construction. This paper discusses the foundation conditions encountered during construction of concrete gravity dam and the associated treatments that were required. To ensure the safety of project, foundation was treated and design adjustments were made. A 2D analysis was carried out using ABAQUS Finite Element Method (FEM) software.},
     year = {2017}
    }
    

    Copy | Download

  • TY  - JOUR
    T1  - Shear Zone Treatment at Dam Foundation Level
    AU  - Ashutosh Anand
    AU  - Somesh Kumar
    AU  - Vivek Tripathi
    Y1  - 2017/11/06
    PY  - 2017
    N1  - https://doi.org/10.11648/j.ajce.20170506.16
    DO  - 10.11648/j.ajce.20170506.16
    T2  - American Journal of Civil Engineering
    JF  - American Journal of Civil Engineering
    JO  - American Journal of Civil Engineering
    SP  - 352
    EP  - 357
    PB  - Science Publishing Group
    SN  - 2330-8737
    UR  - https://doi.org/10.11648/j.ajce.20170506.16
    AB  - Foundation is a critical element for any dam. Understanding the foundation and the required treatment is critical to developing the final dam design. However, the design of the foundation does not end with the final design drawings for the Project. During construction foundation conditions need to be evaluated as excavation and construction proceeds to determine if foundation conditions are consistent with assumptions and expectations. Adjustments to the planned excavation or to the design of the dam, including changes in the grout curtain, dam geometry, and other features are often required during construction. This paper discusses the foundation conditions encountered during construction of concrete gravity dam and the associated treatments that were required. To ensure the safety of project, foundation was treated and design adjustments were made. A 2D analysis was carried out using ABAQUS Finite Element Method (FEM) software.