| Peer-Reviewed

Energy Efficient Lighting System in Gaza Strip Buildings

Received: 8 October 2013    Accepted:     Published: 20 November 2013
Views:       Downloads:
Abstract

This study aimed at identifying design features that can be incorporated in buildings to make them energy efficient. Energy audit and analysis is necessary to increase building energy efficiency. Three methods to increase energy efficiency were selected based on installation cost: the first method of low cost is replacing T-8 fluorescent lamps (FL) and Metal Halide lamps (ML) with T-5 and High Pressure Sodium (HPS) respectively, the second method of medium cost is replacing all FL and ML lamp with Light Emitting Diode (LED), the third method of high cost is the automation system for room lighting based on fuzzy logic controller at some places in the building. Energy audit and analysis was performed on Irada building at Islamic University of Gaza (IUG). Good energy saving were achieved using low cost, medium cost, and high cost methods. Finally, this provided much needed saved power to be reused in Gaza Strip.

Published in Journal of Electrical and Electronic Engineering (Volume 1, Issue 4)
DOI 10.11648/j.jeee.20130104.16
Page(s) 95-100
Creative Commons

This is an Open Access article, distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution and reproduction in any medium or format, provided the original work is properly cited.

Copyright

Copyright © The Author(s), 2024. Published by Science Publishing Group

Keywords

Lighting, Energy, Fluorescent, Light Emitting Diode, Electrical Defect

References
[1] International Energy Agency (IEA), Word Energy Outlook, Middle East and North Africa Insights OECD/IEA, 2005.
[2] W.L.Lee and Hue Chen, " Benchmarking Hong Kong and China Energy Codes for Residential Buildings", Energy and Buildings, P. 1682 –1636, 2008.
[3] Palestinian Energy & Natural Resources Authority (PENRA), Accessed on: 5/3/2013, available at: http://penra.gov.ps/index.php?option=com_content&view=article&id=590:2011-08-24-06-09-43&catid=1:2009-12-29-11-09-44&Itemid=29.
[4] Environmental Resources International Limited (ERi). Lighting Proposal: Replacement of Existing T-8 FL Tube, Accessed on: 16/1/2013, Available at: http://www.erihk.com/lightings.htm.
[5] FL MAXiLIGHT, Energy Efficient Fluorescent Lighting: Product sheet, Accessed on: 5/3/2013 Available at: http:// www.flmaxilight.com.au .
[6] Zhonngtian Light Co., Ltd., LED Tube Light. Accessed on: 29/12/2012, Available at: http://www.ztlights.com .
[7] Alibaba Group. LED Light Replace 150W HPS. Available at: http://www.alibaba.com.
[8] Aryanto Hartoya and Seno Panjaitan, "Development of Automation System for Room Lighting Based on Fuzzy Logic Controller", International Journal of Information and Electronic Engineering, Vol. 2, No. 6, pp. 955-959, November 2012.
[9] Hatem Elaydi, Imad Ibrik, and Eyad Koudary. "Conservation and Management of Electrical Energy in Gaza Strip Using Low Cost Investment." International Journal of Engineering Research and Applications (IJERA). Vol. 2, no. 4, pp.1152- 1157, July-August 2012.
Cite This Article
  • APA Style

    Hatem Elaydi, Zaki Al Qaraa. (2013). Energy Efficient Lighting System in Gaza Strip Buildings. Journal of Electrical and Electronic Engineering, 1(4), 95-100. https://doi.org/10.11648/j.jeee.20130104.16

    Copy | Download

    ACS Style

    Hatem Elaydi; Zaki Al Qaraa. Energy Efficient Lighting System in Gaza Strip Buildings. J. Electr. Electron. Eng. 2013, 1(4), 95-100. doi: 10.11648/j.jeee.20130104.16

    Copy | Download

    AMA Style

    Hatem Elaydi, Zaki Al Qaraa. Energy Efficient Lighting System in Gaza Strip Buildings. J Electr Electron Eng. 2013;1(4):95-100. doi: 10.11648/j.jeee.20130104.16

    Copy | Download

  • @article{10.11648/j.jeee.20130104.16,
      author = {Hatem Elaydi and Zaki Al Qaraa},
      title = {Energy Efficient Lighting System in Gaza Strip Buildings},
      journal = {Journal of Electrical and Electronic Engineering},
      volume = {1},
      number = {4},
      pages = {95-100},
      doi = {10.11648/j.jeee.20130104.16},
      url = {https://doi.org/10.11648/j.jeee.20130104.16},
      eprint = {https://article.sciencepublishinggroup.com/pdf/10.11648.j.jeee.20130104.16},
      abstract = {This study aimed at identifying design features that can be incorporated in buildings to make them energy efficient. Energy audit and analysis is necessary to increase building energy efficiency. Three methods to increase energy efficiency were selected based on installation cost: the first method of  low cost is replacing T-8 fluorescent lamps (FL) and Metal Halide lamps (ML) with T-5 and High Pressure Sodium (HPS) respectively, the second method of medium cost is replacing all FL and ML lamp with Light Emitting Diode (LED), the third method of high cost is the automation system for room lighting based on fuzzy logic controller at some places in the building. Energy audit and analysis was performed on Irada building at Islamic University of Gaza (IUG). Good energy saving were achieved using low cost, medium cost, and high cost methods. Finally, this provided much needed saved power to be reused in Gaza Strip.},
     year = {2013}
    }
    

    Copy | Download

  • TY  - JOUR
    T1  - Energy Efficient Lighting System in Gaza Strip Buildings
    AU  - Hatem Elaydi
    AU  - Zaki Al Qaraa
    Y1  - 2013/11/20
    PY  - 2013
    N1  - https://doi.org/10.11648/j.jeee.20130104.16
    DO  - 10.11648/j.jeee.20130104.16
    T2  - Journal of Electrical and Electronic Engineering
    JF  - Journal of Electrical and Electronic Engineering
    JO  - Journal of Electrical and Electronic Engineering
    SP  - 95
    EP  - 100
    PB  - Science Publishing Group
    SN  - 2329-1605
    UR  - https://doi.org/10.11648/j.jeee.20130104.16
    AB  - This study aimed at identifying design features that can be incorporated in buildings to make them energy efficient. Energy audit and analysis is necessary to increase building energy efficiency. Three methods to increase energy efficiency were selected based on installation cost: the first method of  low cost is replacing T-8 fluorescent lamps (FL) and Metal Halide lamps (ML) with T-5 and High Pressure Sodium (HPS) respectively, the second method of medium cost is replacing all FL and ML lamp with Light Emitting Diode (LED), the third method of high cost is the automation system for room lighting based on fuzzy logic controller at some places in the building. Energy audit and analysis was performed on Irada building at Islamic University of Gaza (IUG). Good energy saving were achieved using low cost, medium cost, and high cost methods. Finally, this provided much needed saved power to be reused in Gaza Strip.
    VL  - 1
    IS  - 4
    ER  - 

    Copy | Download

Author Information
  • Electrical Engineering Department, Islamic University of Gaza, Gaza, Palestine

  • Electrical Engineering Department, Islamic University of Gaza, Gaza, Palestine

  • Sections