Research on Selectivity of Co-processing Protection Methods for Ship Distribution Network Based on Communications
Journal of Electrical and Electronic Engineering
Volume 4, Issue 2, April 2016, Pages: 6-12
Received: Apr. 6, 2016; Published: Apr. 7, 2016
Views 3562      Downloads 163
Authors
Huang Jing, Electrical Engineering Department, School of Electrical Engineering, Naval University of Engineering, Wuhan, China
He Huiying, Electrical Engineering Department, School of Electrical Engineering, Naval University of Engineering, Wuhan, China
Zhou Shiwan, Electrical Engineering Department, School of Electrical Engineering, Naval University of Engineering, Wuhan, China
Zhang Tao, Electrical Engineering Department, School of Electrical Engineering, Naval University of Engineering, Wuhan, China
Article Tools
Follow on us
Abstract
Relaying system is a distributed discrete structure, each protector and detection unit is distributed in logic and physics. In this text, the authors propose a selective protection method of ship distribution network based on the strategy of communication coordinate, designing the protector to intelligent structure which has the function of fault current detection, calculation of current rising rate, communication and coordination processing. For communication coordinated strategy in ship power distribution network, the application of selective protection research, to improve the effectiveness of the selective protection of ship power distribution network is of great significance.
Keywords
Power Distribution Network, Selective Protection, Collaborative Strategy, Communication
To cite this article
Huang Jing, He Huiying, Zhou Shiwan, Zhang Tao, Research on Selectivity of Co-processing Protection Methods for Ship Distribution Network Based on Communications, Journal of Electrical and Electronic Engineering. Vol. 4, No. 2, 2016, pp. 6-12. doi: 10.11648/j.jeee.20160402.11
References
[1]
Liu Qiang. Technology discussion of smart power grid relaying [J]. Jiangsu electrical engineering, 2010(02): 82-84.
[2]
Jiang Xiaoping, Zhang Peng. Design of smart relaying protector [J]. Association for science and technology BBS, 2011(11), 23-24.
[3]
Ji Luming, Zhang Huailiang. Research of ship power distribution network structure [J]. Ship engineering, 2009(02): 35-38.
[4]
Li lin, Shenbing, Zhuang Jinwu. Ship power system [M]. WuHan: The tides press. 2003.
[5]
Yang Hu. Ship power system microcomputer protection and monitoring system research [D]. Wuhan: Huazhong university of science and technology, 2007, 06.
[6]
Mihnko B D, Zoran M. Digital signal processing algorithm for arcing faults detection and fault distance calculation on transmission lines [J]. electrical power and energy system, 2001, 19(3): 165-170.
[7]
Zhang Yongwen, Zhong Xiaoming. The selective protection of technology of low voltage power distribution system [J]. Electrical technology, 2007(09): 59-64.
[8]
Amann N P. A Development of an adaptive protection scheme for shipboard power systems [D]. Mississippi State Univ, 2007.
[9]
BO Z Q. A daptive non-communication protection for power lines BO scheme the delayed operation approach [J]. IEEE Transaction on Power Delivery, 2002, 17(1): 85-91.
[10]
Ding Yixian, Zhao Ruifeng, Le ying. The selective protection of intelligent power distribution system [J]. Low voltage electrical appliances, 2013(08): 44-47.
[11]
Feng Zongheng. Low voltage power distribution system selectivity and equipment selection of over-current protection [J]. Electrical engineering application, 2003(4): 17-23.
[12]
Tu Jian, Zhang Xianhe, Liu Jinhua. [J]. Based on wavelet transform is the traveling wave ranging and protect the selective research of implementation Coal mine safety, 2009(11): 57-60.
[13]
Yin Xianggen, Wang Yang, Zhang Zhe. Zone-division and tripping strategy for limited wide area protection adapting to smart grid [J]. Proceedings of the CSEE, 2010, 30(7): 1-7 (in Chinese).
[14]
Shi Ji. The electric power communication and its application in the smart grid [J]. Digital Technology and Application. 2012(06): 50-51.
ADDRESS
Science Publishing Group
1 Rockefeller Plaza,
10th and 11th Floors,
New York, NY 10020
U.S.A.