As one of the core components in the extreme high voltage power grid, the extreme high voltage transformer has a large rated capacity, and the level of magnetizing inrush current generated by the air-to-air transformer is high. At the same time, a large amount of harmonics are injected into the power grid. In severe cases, a long duration and a slow decay can be generated. The voltage has an adverse effect on the near-area grid and equipment (especially power electronics). In order to further improve the safety and reliability of systems and equipment, effective measures need to be taken to suppress them. At present, the measures that can be used to limit the main transformer closing current include the circuit breaker installation closing resistor and the phase selection closing technology. However, since the closing resistance does not exceed 10 ms, it limits the main transformer closing excitation current, harmonics and over The effect of voltage is relatively limited, and the conventional phase-selection closing technology cannot consider the influence of transformer remanence, and its limiting effect is also not ideal. Foreign research and the use of phase-selection closing technology that takes residual magnetism in some ultra-high-pressure projects to solve the problem of air-to-air inrush current has gained some experience. In theory, this measure is expected to solve the extreme high voltage large-capacity transformer very ideally. Inrush current, harmonics, waveform distortion and overvoltage caused by closing. In this paper, the influencing factors of remanence of extreme high voltage transformers in phase-selective switching technology are studied. According to the research results, the specific scheme of voltage integral to measure residual magnetism is established.

DOI 10.11648/j.jeee.20190702.15
Published in Journal of Electrical and Electronic Engineering (Volume 7, Issue 2, April 2019)
Page(s) 57-63
Creative Commons

This is an Open Access article, distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution and reproduction in any medium or format, provided the original work is properly cited.

Copyright

Copyright © The Author(s), 2024. Published by Science Publishing Group

Keywords

Extreme High Voltage Transformer, Residual Magnetism, Option Switching, Voltage Integral Calculation Method

References
[1] Niu Shuaijie, Zhao Lihua, Chen Ling, et al. Research on Residual Magnetic Resonance Detection Method Based on Time-Current Curve [J]. Electric Measuring & Instrumentation, 2017 (07): 71-75+87.
[2] Zhou Jianping, Luo Jian, ZHOU Jian-ping, et al. An Estimation Method for Residual Magnetism of Transformer Core [J]. Thermal Power Generation, 2010, 39 (3): 61-64.
[3] Xing Yunmin, Luo Jian, Zhou Jianping, et al. Residual Magnet Estimation of Transformer Core [J]. Power System Technology, 2011 (2): 169-172.
[4] He Yuan, Li Xin, Luo Jian. Research on Identification of Transformer Magnetizing Inductance Using Hysteresis Loop [J]. Power System Protection and Control, 2013 (14).
[5] Zhang Xiaojie, Yang Bo, Chen Lei. Research on Calculation Method of Residual Magnetism of Transformer Based on Hysteresis Loop [J]. 1997, 52 (10): 11-13.
[6] Yang Yuyan, Wang Bao. Transformer Model Considering Hysteresis Based on PSCAD V4.6 [J]. Guangdong Electric Power, 2017, 30 (6): 67-72.
[7] Qi Guozheng. Research on Transformer Magnetizing Inrush Current Suppression Technology [D]. 2017.
[8] Ge Wenqi, Wang Youhua, Chen Xueguang, et al. Measurement and weakening method of core remanence in power transformers [J]. Transactions of China Electrotechnical Society, 2015, 30 (16): 10-16.
[9] Huang Jin, Liang Zhaoting. Selection and correlation technology based on residual magnetic measurement [J]. Electrical Apparatus and Energy Efficiency Management Technology, 2011 (9): 10-13.
[10] Wang Yang. Research on Remanence Prediction of Transformer Core [D]. Shandong University, 2017.
[11] Huang Jin. Research on the selection and correlation technology of no-load transformers [D]. 2010.
[12] Ni Haimiao. Research on the method of suppressing the inrush current of the no-load transformer based on phase selection control [D]. 2016.
Author Information
  • Power System Department, China Electric Power Research Institute, Beijing, China

  • Power System Department, China Electric Power Research Institute, Beijing, China

  • Power System Department, China Electric Power Research Institute, Beijing, China

  • School of Electrical Engineering, Beijing Jiaotong University, Beijing, China

  • Power System Department, China Electric Power Research Institute, Beijing, China

  • Shandong Electric Power Research Institute, Jinan, China

Cite This Article
  • APA Style

    Teng Wentao, Xiang Zutao, Zheng Bin, Song Xiuyou, Zhang Yuanyuan, et al. (2019). Study on Factors Affecting Residual Magnetism of Phase Selection of Extreme High Voltage Transformer and Its Calculation Method. Journal of Electrical and Electronic Engineering, 7(2), 57-63. https://doi.org/10.11648/j.jeee.20190702.15

    Copy | Download

    ACS Style

    Teng Wentao; Xiang Zutao; Zheng Bin; Song Xiuyou; Zhang Yuanyuan, et al. Study on Factors Affecting Residual Magnetism of Phase Selection of Extreme High Voltage Transformer and Its Calculation Method. J. Electr. Electron. Eng. 2019, 7(2), 57-63. doi: 10.11648/j.jeee.20190702.15

    Copy | Download

    AMA Style

    Teng Wentao, Xiang Zutao, Zheng Bin, Song Xiuyou, Zhang Yuanyuan, et al. Study on Factors Affecting Residual Magnetism of Phase Selection of Extreme High Voltage Transformer and Its Calculation Method. J Electr Electron Eng. 2019;7(2):57-63. doi: 10.11648/j.jeee.20190702.15

    Copy | Download

  • @article{10.11648/j.jeee.20190702.15,
      author = {Teng Wentao and Xiang Zutao and Zheng Bin and Song Xiuyou and Zhang Yuanyuan and Li Kuan},
      title = {Study on Factors Affecting Residual Magnetism of Phase Selection of Extreme High Voltage Transformer and Its Calculation Method},
      journal = {Journal of Electrical and Electronic Engineering},
      volume = {7},
      number = {2},
      pages = {57-63},
      doi = {10.11648/j.jeee.20190702.15},
      url = {https://doi.org/10.11648/j.jeee.20190702.15},
      eprint = {https://download.sciencepg.com/pdf/10.11648.j.jeee.20190702.15},
      abstract = {As one of the core components in the extreme high voltage power grid, the extreme high voltage transformer has a large rated capacity, and the level of magnetizing inrush current generated by the air-to-air transformer is high. At the same time, a large amount of harmonics are injected into the power grid. In severe cases, a long duration and a slow decay can be generated. The voltage has an adverse effect on the near-area grid and equipment (especially power electronics). In order to further improve the safety and reliability of systems and equipment, effective measures need to be taken to suppress them. At present, the measures that can be used to limit the main transformer closing current include the circuit breaker installation closing resistor and the phase selection closing technology. However, since the closing resistance does not exceed 10 ms, it limits the main transformer closing excitation current, harmonics and over The effect of voltage is relatively limited, and the conventional phase-selection closing technology cannot consider the influence of transformer remanence, and its limiting effect is also not ideal. Foreign research and the use of phase-selection closing technology that takes residual magnetism in some ultra-high-pressure projects to solve the problem of air-to-air inrush current has gained some experience. In theory, this measure is expected to solve the extreme high voltage large-capacity transformer very ideally. Inrush current, harmonics, waveform distortion and overvoltage caused by closing. In this paper, the influencing factors of remanence of extreme high voltage transformers in phase-selective switching technology are studied. According to the research results, the specific scheme of voltage integral to measure residual magnetism is established.},
     year = {2019}
    }
    

    Copy | Download

  • TY  - JOUR
    T1  - Study on Factors Affecting Residual Magnetism of Phase Selection of Extreme High Voltage Transformer and Its Calculation Method
    AU  - Teng Wentao
    AU  - Xiang Zutao
    AU  - Zheng Bin
    AU  - Song Xiuyou
    AU  - Zhang Yuanyuan
    AU  - Li Kuan
    Y1  - 2019/06/15
    PY  - 2019
    N1  - https://doi.org/10.11648/j.jeee.20190702.15
    DO  - 10.11648/j.jeee.20190702.15
    T2  - Journal of Electrical and Electronic Engineering
    JF  - Journal of Electrical and Electronic Engineering
    JO  - Journal of Electrical and Electronic Engineering
    SP  - 57
    EP  - 63
    PB  - Science Publishing Group
    SN  - 2329-1605
    UR  - https://doi.org/10.11648/j.jeee.20190702.15
    AB  - As one of the core components in the extreme high voltage power grid, the extreme high voltage transformer has a large rated capacity, and the level of magnetizing inrush current generated by the air-to-air transformer is high. At the same time, a large amount of harmonics are injected into the power grid. In severe cases, a long duration and a slow decay can be generated. The voltage has an adverse effect on the near-area grid and equipment (especially power electronics). In order to further improve the safety and reliability of systems and equipment, effective measures need to be taken to suppress them. At present, the measures that can be used to limit the main transformer closing current include the circuit breaker installation closing resistor and the phase selection closing technology. However, since the closing resistance does not exceed 10 ms, it limits the main transformer closing excitation current, harmonics and over The effect of voltage is relatively limited, and the conventional phase-selection closing technology cannot consider the influence of transformer remanence, and its limiting effect is also not ideal. Foreign research and the use of phase-selection closing technology that takes residual magnetism in some ultra-high-pressure projects to solve the problem of air-to-air inrush current has gained some experience. In theory, this measure is expected to solve the extreme high voltage large-capacity transformer very ideally. Inrush current, harmonics, waveform distortion and overvoltage caused by closing. In this paper, the influencing factors of remanence of extreme high voltage transformers in phase-selective switching technology are studied. According to the research results, the specific scheme of voltage integral to measure residual magnetism is established.
    VL  - 7
    IS  - 2
    ER  - 

    Copy | Download

  • Sections