Study of Short-circuit Faults Affecting Electrical Networks

Received: 24 November 2025     Accepted: 5 December 2025     Published: 30 December 2025
Views:       Downloads:
Abstract

Most faults in power lines are caused by short circuits resulting from phenomena such as lightning, severe weather, or power surges linked to circuit breaker operations. These short circuits, whether temporary or permanent, require accurate detection and location to enable rapid repair and restoration of power supply. To protect the system against short-circuit currents, which can cause irreversible damage to key equipment, it is essential to quickly disconnect the faulty part of the network. In order to correctly size this equipment, it is essential to estimate the magnitude of the currents likely to flow during a short circuit. This study involved calculating single-phase short-circuit currents in the event of a fault on the Cable, Soluxe, Airoport, Talladje, and Gawaye feeders at the Niamey3 electrical substation. The method used to calculate short-circuit currents in HTB and HTA networks is based on the principle of symmetrical components. This method was chosen for its accuracy and analytical nature. The results obtained show that the Soluxe feeder has the highest short-circuit current, with a value of 1.95 kA, compared to those of the Cable, Airoport, Talladje, and Gawaye feeders, which are 1.86 kA, 0.67 kA, 0.64 kA, and 0.56 kA, respectively. This is explained by the fact that the calculated impedances (direct, inverse, and zero-sequence) of this feeder are lower than those of the other four feeders.

Published in International Journal of Energy and Power Engineering (Volume 14, Issue 6)
DOI 10.11648/j.ijepe.20251406.11
Page(s) 142-150
Creative Commons

This is an Open Access article, distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution and reproduction in any medium or format, provided the original work is properly cited.

Copyright

Copyright © The Author(s), 2025. Published by Science Publishing Group

Keywords

References
[1] Loiy Rashed Almobasher, Ibrahim Omar A Habiballah, Review of Power System Faults, International Journal of Engineering Research & Technology, 9, 61-64 (2020).
[2] Neha Kumari, "Power System Faults: A Review," International Journal of Engineering Research & Technology (IJERT), 2016.
[3] B. de Metz-Noblat, F. Dumas, C. Poulain, « Calculation of short-circuit currents », Cahier technique no. 158, updated September 2005.
[4] BELBEY Mourad “Study and calculation of symmetrical and permanent three-phase short-circuit currents,” final thesis, Mouloud Mammeri University of Tizi-Ouzou, 2013/2014.
[5] Bedel Giscard Onana Essama1 and al. “Electrical Network Influenced by overload, broken phase and short-circuit” ISAR Journal of Science and Technology, Vol-1, Iss-1 (Nov- 2023): 12-20.
[6] Liu, L.; Li, X.; Teng, Y.; Luo, Y.; Chen, K. Improved Commutation Failure Prevention Control for Inter- Phase Short-Circuit Faults. Appl. Sci. 2025, 15, 9972.
Cite This Article
  • APA Style

    Soumaïla, N. T., Nassirou, A. H. M., Moustapha, A. K. M., Moussa, I. I., Seibou, B. (2025). Study of Short-circuit Faults Affecting Electrical Networks. International Journal of Energy and Power Engineering, 14(6), 142-150. https://doi.org/10.11648/j.ijepe.20251406.11

    Copy | Download

    ACS Style

    Soumaïla, N. T.; Nassirou, A. H. M.; Moustapha, A. K. M.; Moussa, I. I.; Seibou, B. Study of Short-circuit Faults Affecting Electrical Networks. Int. J. Energy Power Eng. 2025, 14(6), 142-150. doi: 10.11648/j.ijepe.20251406.11

    Copy | Download

    AMA Style

    Soumaïla NT, Nassirou AHM, Moustapha AKM, Moussa II, Seibou B. Study of Short-circuit Faults Affecting Electrical Networks. Int J Energy Power Eng. 2025;14(6):142-150. doi: 10.11648/j.ijepe.20251406.11

    Copy | Download

  • @article{10.11648/j.ijepe.20251406.11,
      author = {Noma Talibi Soumaïla and Abdou Hamidine Mamane Nassirou and Attoumane Kosso Mamadou Moustapha and Insa Issoufou Moussa and Boureima Seibou},
      title = {Study of Short-circuit Faults Affecting Electrical Networks},
      journal = {International Journal of Energy and Power Engineering},
      volume = {14},
      number = {6},
      pages = {142-150},
      doi = {10.11648/j.ijepe.20251406.11},
      url = {https://doi.org/10.11648/j.ijepe.20251406.11},
      eprint = {https://article.sciencepublishinggroup.com/pdf/10.11648.j.ijepe.20251406.11},
      abstract = {Most faults in power lines are caused by short circuits resulting from phenomena such as lightning, severe weather, or power surges linked to circuit breaker operations. These short circuits, whether temporary or permanent, require accurate detection and location to enable rapid repair and restoration of power supply.  To protect the system against short-circuit currents, which can cause irreversible damage to key equipment, it is essential to quickly disconnect the faulty part of the network. In order to correctly size this equipment, it is essential to estimate the magnitude of the currents likely to flow during a short circuit. This study involved calculating single-phase short-circuit currents in the event of a fault on the Cable, Soluxe, Airoport, Talladje, and Gawaye feeders at the Niamey3 electrical substation. The method used to calculate short-circuit currents in HTB and HTA networks is based on the principle of symmetrical components. This method was chosen for its accuracy and analytical nature. The results obtained show that the Soluxe feeder has the highest short-circuit current, with a value of 1.95 kA, compared to those of the Cable, Airoport, Talladje, and Gawaye feeders, which are 1.86 kA, 0.67 kA, 0.64 kA, and 0.56 kA, respectively. This is explained by the fact that the calculated impedances (direct, inverse, and zero-sequence) of this feeder are lower than those of the other four feeders.},
     year = {2025}
    }
    

    Copy | Download

  • TY  - JOUR
    T1  - Study of Short-circuit Faults Affecting Electrical Networks
    AU  - Noma Talibi Soumaïla
    AU  - Abdou Hamidine Mamane Nassirou
    AU  - Attoumane Kosso Mamadou Moustapha
    AU  - Insa Issoufou Moussa
    AU  - Boureima Seibou
    Y1  - 2025/12/30
    PY  - 2025
    N1  - https://doi.org/10.11648/j.ijepe.20251406.11
    DO  - 10.11648/j.ijepe.20251406.11
    T2  - International Journal of Energy and Power Engineering
    JF  - International Journal of Energy and Power Engineering
    JO  - International Journal of Energy and Power Engineering
    SP  - 142
    EP  - 150
    PB  - Science Publishing Group
    SN  - 2326-960X
    UR  - https://doi.org/10.11648/j.ijepe.20251406.11
    AB  - Most faults in power lines are caused by short circuits resulting from phenomena such as lightning, severe weather, or power surges linked to circuit breaker operations. These short circuits, whether temporary or permanent, require accurate detection and location to enable rapid repair and restoration of power supply.  To protect the system against short-circuit currents, which can cause irreversible damage to key equipment, it is essential to quickly disconnect the faulty part of the network. In order to correctly size this equipment, it is essential to estimate the magnitude of the currents likely to flow during a short circuit. This study involved calculating single-phase short-circuit currents in the event of a fault on the Cable, Soluxe, Airoport, Talladje, and Gawaye feeders at the Niamey3 electrical substation. The method used to calculate short-circuit currents in HTB and HTA networks is based on the principle of symmetrical components. This method was chosen for its accuracy and analytical nature. The results obtained show that the Soluxe feeder has the highest short-circuit current, with a value of 1.95 kA, compared to those of the Cable, Airoport, Talladje, and Gawaye feeders, which are 1.86 kA, 0.67 kA, 0.64 kA, and 0.56 kA, respectively. This is explained by the fact that the calculated impedances (direct, inverse, and zero-sequence) of this feeder are lower than those of the other four feeders.
    VL  - 14
    IS  - 6
    ER  - 

    Copy | Download

Author Information
  • Department of Physics, Abdou Moumouni University of Niamey, Niamey, Niger

  • Department of Electrical Engineering, School of Mining Industry and Geology, Niamey, Niger

  • Department of Electrical Engineering, School of Mining Industry and Geology, Niamey, Niger

  • Department of Electrical Engineering, School of Mining Industry and Geology, Niamey, Niger

  • Department of Electrical Engineering, School of Mining Industry and Geology, Niamey, Niger

  • Sections