Abstract: After Unit 2 is put into operation, the oil leakage in the middle of the steam and excitation ends of the generator is relatively large, which affects the safety of production. The causes of oil leakage are analyzed, and temporary measures are taken to prevent major equipment damage during operation. Taking advantage of the opportunity of unit maintenance, the upper end cap of generator steam end and excitation end is disintegrated. It is found that the middle side sealant strip is not filled, which causes insufficient deformation of the sealant strip. The gap between oil seal, oil holder and sealing bush is repaired and adjusted. In the process of overhaul, the organization, safety and technical measures are strictly implemented, and the "four-stage" acceptance is carried out to completely eliminate the oil leakage of turbogenerator.Abstract: After Unit 2 is put into operation, the oil leakage in the middle of the steam and excitation ends of the generator is relatively large, which affects the safety of production. The causes of oil leakage are analyzed, and temporary measures are taken to prevent major equipment damage during operation. Taking advantage of the opportunity of unit main...Show More
Abstract: Connecting board parts are mainly used in all kinds of containers to fix all kinds of containers, cargo and so on. Whether the fixed objects are reliable and the operation is convenient directly affects the working efficiency of connecting board. The connecting board is supported on the axle and the two panels are perpendicular to 90 degrees. When processing, the technical requirements of drawing must be met in order to achieve the use effect. Therefore, the connecting board should be mechanically added reasonably. Only by analyzing the process and designing the appropriate fixture for mechanical processing can the better performance be brought into play.Abstract: Connecting board parts are mainly used in all kinds of containers to fix all kinds of containers, cargo and so on. Whether the fixed objects are reliable and the operation is convenient directly affects the working efficiency of connecting board. The connecting board is supported on the axle and the two panels are perpendicular to 90 degrees. When ...Show More