Hybrid-powered telecommunication sites operate as tightly coupled cyber-physical systems in which renewable generation, grid availability, battery condition, radio traffic, cooling demand, weather, and telemetry quality evolve on different but interacting time scales. Conventional monitoring pipelines generally treat these variables as independent time-series features and provide point forecasts that do not explicitly represent topology, uncertainty, or the operational consequences of prediction errors. This study proposes a graph-temporal probabilistic digital twin (GT-PDT) for uncertainty-aware real-time monitoring and supervisory control of hybrid-powered telecommunication sites. The proposed information model represents energy sources, converters, storage units, loads, radio subsystems, environmental variables, and measurements as typed nodes and relations in a dynamic graph, while retaining observation time, data-quality confidence, model provenance, and operating constraints. A graph-temporal forecasting layer estimates conditional quantiles rather than a single deterministic value, and calibrated predictive uncertainty is used to drive an event-based acquisition automaton that adaptively switches among 60, 10, 5, and 1 s sampling intervals according to entropy growth, forecast spread, and safety residuals. The resulting probabilistic forecasts are integrated into a scenario-based model predictive controller that jointly minimizes electricity cost, renewable-energy curtailment, battery ageing, diesel-generator use, and telecommunication service risk. The framework is assessed on a reproducible 30-day synthetic site that includes correlated solar and wind resources, traffic-dependent radio demand, cooling dynamics, grid interruptions, measurement faults, and asynchronous observations. On the holdout period, GT-PDT achieves a MAPE of 3.73%, RMSE of 0.159, and R2 of 0.943, outperforming seasonal persistence and temporal-only baselines. After calibration, the nominal 90% prediction interval attains 89.3% empirical coverage; the complete event-detection configuration reaches an F1 score of 86.2% while reducing telemetry messages to 44% of the fixed-sampling baseline. In the illustrative supervisory experiment, probabilistic GT-PDT control lowers operating cost from USD 151.4 to USD 119.8, diesel consumption from 156 to 69 kWh, and QoS-risk exposure from 42 to 14 min, while increasing renewable-energy utilization to 83.1%. These results constitute methodological evidence from a controlled synthetic testbed rather than field-certified performance. The principal contribution is an integrated, traceable monitoring architecture that connects relational state estimation, calibrated uncertainty, adaptive sensing, and risk-aware control within a single digital-twin framework for resilient telecommunication energy management.
| Published in | Communications (Volume 13, Issue 2) |
| DOI | 10.11648/j.com.20261302.11 |
| Page(s) | 17-23 |
| Creative Commons |
This is an Open Access article, distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution and reproduction in any medium or format, provided the original work is properly cited. |
| Copyright |
Copyright © The Author(s), 2026. Published by Science Publishing Group |
Telecommunication Site, Hybrid Power, Heterogeneous Graph, Probabilistic Forecasting, Event-driven Sensing, Model Predictive Control, Digital Twin
Dimension | Conventional pipeline | GT-PDT |
|---|---|---|
Representation | feature matrix | typed dynamic graph |
Forecast output | single estimate | conditional quantiles |
Sampling | fixed interval | value-of-information event |
Decision link | post-processing | scenario MPC |
Traceability | model-level | node/edge/forecast/action |
Object | Required fields | Purpose |
|---|---|---|
Node | asset ID, type, rating, site | physical identity |
Edge | source, target, relation, limit | topology/constraint |
Observation | event/arrival time, value, unit | asynchronous state |
Quality | validity, uncertainty, latency | evidence strength |
Forecast | quantile, horizon, model version | future distribution |
Action | set-point, reason, safety gate | audit trail |
State | Entry evidence | Sampling | Exit condition |
|---|---|---|---|
Quiet | low entropy; balance valid | 60 s | entropy increase |
Track | forecast spread widening | 10 s | resolved or risk rise |
Critical | safety residual / outage | 1 s | protected response |
Recovery | post-event verification | 5 s | stable evidence |
Dimension | Metric | Acceptance question |
|---|---|---|
Point accuracy | MAPE, RMSE, R2 | Is the median useful? |
Uncertainty | coverage, interval width | Are risks calibrated? |
Localization | event F1, node attribution | Is the cause traceable? |
Operations | cost, diesel, QoS risk | Does control create value? |
Efficiency | messages, edge latency | Is adaptation affordable? |
Method | MAPE% | RMSE | R2 |
|---|---|---|---|
Seasonal persistence | 6.05 | 0.275 | 0.830 |
Temporal-only encoder | 4.93 | 0.210 | 0.901 |
Graph without quantiles | 3.85 | 0.165 | 0.939 |
GT-PDT | 3.73 | 0.159 | 0.943 |
Variant | Event F1% | 90% coverage | Messages% |
|---|---|---|---|
Fixed sampling | 40.0 | 72.4 | 100 |
No graph edges | 80.0 | 81.6 | 63 |
No calibration | 80.0 | 84.1 | 57 |
Complete GT-PDT | 86.2 | 89.3 | 44 |
Policy | Cost $ | Diesel kWh | RES use% | QoS-risk min |
|---|---|---|---|---|
Rule schedule | 151.4 | 156 | 72.1 | 42 |
Point-forecast MPC | 132.6 | 101 | 78.8 | 29 |
Probabilistic GT-PDT | 119.8 | 69 | 83.1 | 14 |
GT-PDT | Graph-Temporal Probabilistic Digital Twin |
MAPE | Mean Absolute Percentage Error |
MPC | Media Player Classic |
RMSE | Root Mean Squared Error |
| [1] | M. Amir, Zaheeruddin, and A. Haque, “Intelligent based hybrid renewable energy resources forecasting and real time power demand management system for resilient energy systems,” Science Progress, vol. 105, no. 4, 2022, |
| [2] | M. A. Oukebdane, A. F. M. S. Shah, M. B. Islam, J. Ekoru, and M. Madahana, “Hybrid model for 6G network traffic prediction and wireless resource optimization,” IEEE Access, vol. 13, pp. 142129-142139, 2025, |
| [3] | Sultan, A. Energy Efficiency in 3GPP Technologies. 3GPP, 2024. Available at: |
| [4] | ETSI. Environmental Engineering (EE); Monitoring and Control Interface for Infrastructure Equipment (Power, Cooling and Building Environment Systems used in Telecommunication Networks); Part 1: Generic Interface. ETSI ES 202 336-1 V1.3.1, 2025. |
| [5] |
ETSI. Environmental Engineering (EE); Monitoring and Control Interface for Infrastructure Equipment (Power, Cooling and Building Environment Systems used in Telecommunication Networks); Part 9: Alternative Power Systems. ETSI ES 202 336-9 V1.1.1, 2012.
https://www.etsi.org/deliver/etsi_es/202300_202399/20233609/01.01.01_60/es_20233609v010101p.pdf |
| [6] | ETSI. Environmental Engineering (EE); Monitoring and control interface for infrastructure equipment (Power, Cooling and environment systems used in telecommunication networks); Part 11: Battery system with integrated control and monitoring information model. ETSI ES 202 336-11 V1.2.1, 2025. |
| [7] | ETSI. Environmental Engineering (EE); Monitoring and Control Interface for Infrastructure Equipment (Power, Cooling and Building Environment Systems used in Telecommunication Networks); Part 12: ICT Equipment Power, Energy and Environmental Parameters Monitoring Information Model. ETSI ES 202 336-12 V1.3.1, 2025. |
| [8] |
Banks, A., Briggs, E., Borgendale, K., Gupta, R. MQTT Version 5.0. OASIS Standard, 2019.
https://docs.oasis-open.org/mqtt/mqtt/v5.0/os/mqtt-v5.0-os.html |
| [9] | G. Ali, H. Aly, and T. Little, “Automatic generation control of a multi-area hybrid renewable energy system using a proposed novel GA-fuzzy logic self-tuning PID controller,” Energies, vol. 17, Art. no. 2000, 2024, |
| [10] | R. V. Klyuev, A. D. Morgoeva, O. A. Gavrina, I. I. Bosikov, and I. D. Morgoev, “Forecasting planned electricity consumption for an interconnected power system using machine learning,” Journal of Mining Institute, vol. 261, pp. 392-402, 2023. |
| [11] | M. A. Sobirov, I. Sh. Kurbanova, and Z. O. Sabirova, “Multi-level approach in organizing the energy supply system in telecommunication networks,” in Proc. IEEE APEIE, 2023, pp. 1830-1834, |
| [12] | Yousef, L. A., Yousef, H., Rocha-Meneses, L. Artificial Intelligence for Management of Variable Renewable Energy Systems: A Review of Current Status and Future Directions. Energies. 2023, 16(24), 8057. |
| [13] | Liu, X., Zhang, X., Baziar, A. Hybrid Machine Learning and Modified Teaching Learning-Based English Optimization Algorithm for Smart City Communication. Sustainability. 2023, 15(15), 11535. |
| [14] | Arévalo-Cordero, P., González, F., Martínez, A., Zarie, D., Rodas, A., Albornoz, E., Ochoa-Correa, D., Benavides, D. Hybrid LSTM-FACTS Control Strategy for Voltage and Frequency Stability in EV-Penetrated Microgrids. Technologies. 2025, 13(9), 402. |
| [15] | Kazemi Naeini, H., Shomali, R., Pishahang, A., Hasanzadeh, H., Asadi, S., Gholizadeh Lonbar, A. PINN-DT: Optimizing Energy Consumption in Smart Building Using Hybrid Physics-Informed Neural Networks and Digital Twin Framework with Blockchain Security. Sensors. 2025, 25(19), 6242. |
| [16] | Chang, X., Li, S., Wang, Q., Ji, L., Huang, B. Digital Twin-Enabled Distributed Robust Scheduling for Park-Level Integrated Energy Systems. Energies. 2025, 18(24), 6471. |
| [17] | Madani, S. S., Shabeer, Y., Fowler, M., Panchal, S., Chaoui, H., Mekhilef, S., Dou, S. X., See, K. Artificial Intelligence and Digital Twin Technologies for Intelligent Lithium-Ion Battery Management Systems: A Comprehensive Review of State Estimation, Lifecycle Optimization, and Cloud-Edge Integration. Batteries. 2025, 11(8), 298. |
| [18] | ISO. Energy management systems—Requirements with guidance for use. ISO 50001: 2018, 2018. |
| [19] | IEC. Electromagnetic Compatibility (EMC) - Part 4-30: Testing and Measurement Techniques - Power Quality Measurement Methods. IEC 61000-4-30: 2015, 2015. |
| [20] | ITU-T. Energy efficiency metrics and measurement methods for telecommunication equipment. Recommendation ITU-T L.1310, 2020. |
| [21] | Graves, A. Supervised Sequence Labelling with Recurrent Neural Networks. Berlin: Springer, 2012. |
| [22] | Zeng, Q., Sun, Q., Chen, G., Duan, H., Li, C., Song, G. Traffic Prediction of Wireless Cellular Networks Based on Deep Transfer Learning and Cross-Domain Data. IEEE Access. 2020, 8, 172387-172397. |
APA Style
Azatovich, S. M. (2026). A Graph-Temporal Information Model for Uncertainty-Aware Monitoring of Hybrid-Powered Telecommunication Sites. Communications, 13(2), 17-23. https://doi.org/10.11648/j.com.20261302.11
ACS Style
Azatovich, S. M. A Graph-Temporal Information Model for Uncertainty-Aware Monitoring of Hybrid-Powered Telecommunication Sites. Communications. 2026, 13(2), 17-23. doi: 10.11648/j.com.20261302.11
@article{10.11648/j.com.20261302.11,
author = {Sobirov Muzaffar Azatovich},
title = {A Graph-Temporal Information Model for Uncertainty-Aware Monitoring of Hybrid-Powered Telecommunication Sites},
journal = {Communications},
volume = {13},
number = {2},
pages = {17-23},
doi = {10.11648/j.com.20261302.11},
url = {https://doi.org/10.11648/j.com.20261302.11},
eprint = {https://article.sciencepublishinggroup.com/pdf/10.11648.j.com.20261302.11},
abstract = {Hybrid-powered telecommunication sites operate as tightly coupled cyber-physical systems in which renewable generation, grid availability, battery condition, radio traffic, cooling demand, weather, and telemetry quality evolve on different but interacting time scales. Conventional monitoring pipelines generally treat these variables as independent time-series features and provide point forecasts that do not explicitly represent topology, uncertainty, or the operational consequences of prediction errors. This study proposes a graph-temporal probabilistic digital twin (GT-PDT) for uncertainty-aware real-time monitoring and supervisory control of hybrid-powered telecommunication sites. The proposed information model represents energy sources, converters, storage units, loads, radio subsystems, environmental variables, and measurements as typed nodes and relations in a dynamic graph, while retaining observation time, data-quality confidence, model provenance, and operating constraints. A graph-temporal forecasting layer estimates conditional quantiles rather than a single deterministic value, and calibrated predictive uncertainty is used to drive an event-based acquisition automaton that adaptively switches among 60, 10, 5, and 1 s sampling intervals according to entropy growth, forecast spread, and safety residuals. The resulting probabilistic forecasts are integrated into a scenario-based model predictive controller that jointly minimizes electricity cost, renewable-energy curtailment, battery ageing, diesel-generator use, and telecommunication service risk. The framework is assessed on a reproducible 30-day synthetic site that includes correlated solar and wind resources, traffic-dependent radio demand, cooling dynamics, grid interruptions, measurement faults, and asynchronous observations. On the holdout period, GT-PDT achieves a MAPE of 3.73%, RMSE of 0.159, and R2 of 0.943, outperforming seasonal persistence and temporal-only baselines. After calibration, the nominal 90% prediction interval attains 89.3% empirical coverage; the complete event-detection configuration reaches an F1 score of 86.2% while reducing telemetry messages to 44% of the fixed-sampling baseline. In the illustrative supervisory experiment, probabilistic GT-PDT control lowers operating cost from USD 151.4 to USD 119.8, diesel consumption from 156 to 69 kWh, and QoS-risk exposure from 42 to 14 min, while increasing renewable-energy utilization to 83.1%. These results constitute methodological evidence from a controlled synthetic testbed rather than field-certified performance. The principal contribution is an integrated, traceable monitoring architecture that connects relational state estimation, calibrated uncertainty, adaptive sensing, and risk-aware control within a single digital-twin framework for resilient telecommunication energy management.},
year = {2026}
}
TY - JOUR T1 - A Graph-Temporal Information Model for Uncertainty-Aware Monitoring of Hybrid-Powered Telecommunication Sites AU - Sobirov Muzaffar Azatovich Y1 - 2026/11/24 PY - 2026 N1 - https://doi.org/10.11648/j.com.20261302.11 DO - 10.11648/j.com.20261302.11 T2 - Communications JF - Communications JO - Communications SP - 17 EP - 23 PB - Science Publishing Group SN - 2328-5923 UR - https://doi.org/10.11648/j.com.20261302.11 AB - Hybrid-powered telecommunication sites operate as tightly coupled cyber-physical systems in which renewable generation, grid availability, battery condition, radio traffic, cooling demand, weather, and telemetry quality evolve on different but interacting time scales. Conventional monitoring pipelines generally treat these variables as independent time-series features and provide point forecasts that do not explicitly represent topology, uncertainty, or the operational consequences of prediction errors. This study proposes a graph-temporal probabilistic digital twin (GT-PDT) for uncertainty-aware real-time monitoring and supervisory control of hybrid-powered telecommunication sites. The proposed information model represents energy sources, converters, storage units, loads, radio subsystems, environmental variables, and measurements as typed nodes and relations in a dynamic graph, while retaining observation time, data-quality confidence, model provenance, and operating constraints. A graph-temporal forecasting layer estimates conditional quantiles rather than a single deterministic value, and calibrated predictive uncertainty is used to drive an event-based acquisition automaton that adaptively switches among 60, 10, 5, and 1 s sampling intervals according to entropy growth, forecast spread, and safety residuals. The resulting probabilistic forecasts are integrated into a scenario-based model predictive controller that jointly minimizes electricity cost, renewable-energy curtailment, battery ageing, diesel-generator use, and telecommunication service risk. The framework is assessed on a reproducible 30-day synthetic site that includes correlated solar and wind resources, traffic-dependent radio demand, cooling dynamics, grid interruptions, measurement faults, and asynchronous observations. On the holdout period, GT-PDT achieves a MAPE of 3.73%, RMSE of 0.159, and R2 of 0.943, outperforming seasonal persistence and temporal-only baselines. After calibration, the nominal 90% prediction interval attains 89.3% empirical coverage; the complete event-detection configuration reaches an F1 score of 86.2% while reducing telemetry messages to 44% of the fixed-sampling baseline. In the illustrative supervisory experiment, probabilistic GT-PDT control lowers operating cost from USD 151.4 to USD 119.8, diesel consumption from 156 to 69 kWh, and QoS-risk exposure from 42 to 14 min, while increasing renewable-energy utilization to 83.1%. These results constitute methodological evidence from a controlled synthetic testbed rather than field-certified performance. The principal contribution is an integrated, traceable monitoring architecture that connects relational state estimation, calibrated uncertainty, adaptive sensing, and risk-aware control within a single digital-twin framework for resilient telecommunication energy management. VL - 13 IS - 2 ER -